Ada compliance can be overwhelming and we want to help.
Ada restroom stall door requirements.
The minimum width of the stall is 60 inches 1525 mm.
Certain ada compliance issues seem to crop up more frequently than others but it s important to note that the following is not an exhaustive list.
Alterations to the meet the readily achievable requirements of title iii of the americans with disabilities act may be limited the actual work of the project.
4 13 12 automatic doors and power assisted doors.
Or for answers to.
This guide explains requirements in the ada standards for clear floor or ground space and turning space.
A 36 stall door is used most often with a wheel fitting through that opening.
Figure 30 a standard stall.
The ada compliant restroom.
Alterations to entrances toilet facilities elevators steps handrails to meet the accessibility requirements may be limited to the actual work of the project.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
Figure 30 a standard stall.
The centerline of the water closet is 18 inches 455 mm from the side wall.
Need help ordering ada compliant restroom materials.
Toilet rooms can be configured in many different ways but the same requirements apply including those for fixtures doors and turning space.
5 common ada restroom compliance mistakes.
To see all of the ada compliance requirements see the 2010 ada standards for accessible design at www ada gov.
This example shows a door swing located outside fixture clearances obviating the need for wheelchair space beyond the arc of the door swing and turning space free of any overlapping elements left.
Users shouldn t have to exert more than 5 pounds of force to use the faucet to meet ada requirements.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
If an automatic door is used then it shall comply with ansi bhma a156 10 1985.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
When ordering ada bathroom toilet stalls please send us your plans so we can quote you.
Ada compliant urinals should be stall type or wall hung at a maximum of 17 inches from the floor.
Examples of ada toilet stalls.
Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbf 66 6n to stop door movement.
Slowly opening low powered automatic doors shall comply with ansi a156 19 1984.